8,076 research outputs found
Recommended from our members
Influence of semicon shields on the dielectric loss of XLPE cables
Dielectric response measurement techniques in both time and frequency domains are studied in order to measure the dielectric loss of XLPE cables, which have very low losses. A high sensitivity transformer ratio bridge system, which can measure loss tangents as low as 10-5, has been developed with the ability to measure these cables. A tuned amplifier was designed to help to extend the frequency range from 200Hz to 20kHz. Different model cables from Borealis AB with different semiconducting materials have been measured in the temperature range 15ā°C to 120ā°C. It is found that the semiconducting layers dominate the dielectric loss in the insulation system of the XLPE cables, when the outer semicon is treated as measuring electrode. In this case, steadily increasing dielectric loss has been measured at higher frequencies. The resistivity of the semiconducting materials was measured, which confirmed that the increasing slope is due to the semiconducting layers. After using conductive tapes to wrap the cable samples, monotonically decreasing losses were measured, corresponding to the actual dielectric frequency response of the XLPE cables. It is concluded that the axial resistance of semiconducting shields have a substantial influence on the dielectric loss of XLPE cables, especially for dielectric response in high frequency range. A device on measuring the loss of such cables is presented
How to protect a wind turbine from lightning
Techniques for reducing the chances of lightning damage to wind turbines are discussed. The methods of providing a ground for a lightning strike are discussed. Then details are given on ways to protect electronic systems, generating and power equipment, blades, and mechanical components from direct and nearby lightning strikes
Recommended from our members
The measurement of very low conductivity and dielectric loss in XLPE cables: A possible method to detect degradation due to thermal aging
The dielectric response of crosslinked polyethylene (XLPE) insulated, miniature power cables, extruded with inner and outer semicons, was measured over the frequency range 10-4 to 104 Hz at temperatures from 20 to 100 Ā°C. A dielectric spectrometer was used for the frequency range 10-4 to 10-2 Hz. A bespoke noise-free power supply was constructed and used to measure the dc conductivity and, using a Fourier transform technique, it was also used to measure the very low dielectric tanĪ“ losses encountered at frequencies of 1 to 100 Hz. TanĪ“ measurements of <;10-5 were found in this frequency range and attributed to a Ī²-mode dielectric relaxation lying above 100 Hz due to motion of chain segments in the amorphous region and an Ī²-mode relaxation lying below 1 Hz window due to twists of chains in the crystal lamellae. The dc conductivity measurements were consistent with those of the dielectric spectrometer and indicate lower dc conductivities in vacuum degassed cables than have been previously reported for XLPE (less than 10-17 S.m-1). The conduction process is thermally activated with an activation energy of approximately 1.1 eV. Higher conductivities were found for non-degassed cables. A transformer ratio bridge was used for measurements in the range 1 to 10 kHz; loss in this region was shown to be due to the series resistance of the semicon layers. Thermal ageing of the cables at 135 Ā°C for 60 days caused significant increases in the conductivity and tanĪ“ and it is considered that such measurements may be a sensitive way of measuring electrical degradation due to thermal aging
Recommended from our members
Dielectric spectroscopy study of thermally-aged extruded model power cables
āModelā extruded power cables, having a much reduced geometry but using the same extrusion techniques and materials as full-sized cables, have been examined using dielectric spectroscopy techniques to study their thermal ageing effects. Cables insulated with homo-polymer XLPE and co-polymer of XLPE with micron-sized ethylene-butyl-acrylate (EBA) islands were studied by both frequency-domain and time-domain dielectric spectroscopy techniques after accelerated thermal ageing under 135Ā°C for 60 days. In the frequency domain, a frequency response analyzer (FRA) was used to measure the frequency range from 10-4Hz to 1Hz at temperatures from 20Ā°C to 80Ā°C. In the time domain, a special charging/discharging current measurement system was developed to measure the frequencies from 10-1Hz to 102Hz. These techniques were chosen to cope with the extremely low dielectric losses of the model cables. The results are compared with those from new model power cables that were degassed at 80Ā°C for 5 days. Thermal ageing was found to increase the low-frequency conductivity, permittivity and the discharging current. Both homo- and co-polymer cables have substantial increase of dielectric loss after ageing
Formal Verification of a Gain Scheduling Control Scheme
Gain scheduling is a commonly used closed-loop control approach for safety critical non-linear systems, such as commercial gas turbine engines. It is preferred over more advanced control strategies due to a known route to certification. Nonetheless, the stability of the system is hard to prove analytically, and consequently, safety and airworthiness is achieved by burdensome extensive testing. Model checking can aid in bringing down development costs of such a control system and simultaneously improve safety by providing guarantees on properties of embedded control systems. Due to model-checking exhaustive verification capabilities, it has long been recognised that coverage and error-detection rate can be increased compared to traditional testing methods. However, the statespace explosion is still a major computational limitation when applying model-checking to verify dynamic system behaviour. A practical methodology to incrementally design and formally verify control system requirements for a gain scheduling scheme is demonstrated in this paper, overcoming the computational constraints traditionally imposed by model checking. In this manner, the gain-scheduled controller can be efficiently and safely generated with the aid of the model checker
Results and Lessons from a Decade of Terra MODIS On-Orbit Spectral Characterization
Since its launch in December 1999, the NASA EOS Terra MODIS has successfully operated for more than a decade. MODIS makes observations in 36 spectral bands from visible (VIS) to longwave infrared (LWIR) and at three nadir spatial resolutions: 250m (2 bands), 500m (5 bands), and 1km (29 bands). In addition to its on-board calibrators designed for the radiometric calibration, MODIS was built with a unique device, called the spectro-radiometric calibration assembly (SRCA). It can be configured in three different modes: radiometric, spatial, and spectral. When it is operated in the spectral modes, the SRCA can monitor changes in Sensor spectral performance for the VIS and near-infrared (NIR) spectral bands. For more than 10 years, the SRCA operation has continued to provide valuable information for MODIS on-orbit spectral performance. This paper briefly describes SRCA on-orbit operation and calibration activities; it presents decade-long spectral characterization results for Terra MODIS VIS and NIR spectral bands in terms of chances in their center wavelengths (CW) and bandwidths (BW). It is shown that the SRCA on-orbit wavelength calibration capability remains satisfactory. For most spectral bands, the changes in CW and BW are less than 0.5 and 1 nm, respectively. Results and lessons from Terra MODIS on-orbit spectral characterization have and will continue to benefit its successor, Aqua MODIS, and other future missions
Internal Vortex Structure of a Trapped Spinor Bose-Einstein Condensate
The internal vortex structure of a trapped spin-1 Bose-Einstein condensate is
investigated. It is shown that it has a variety of configurations depending on,
in particular, the ratio of the relevant scattering lengths and the total
magnetization.Comment: replacement; minor grammatical corrections but with additional
figure
Gapless finite- theory of collective modes of a trapped gas
We present predictions for the frequencies of collective modes of trapped
Bose-condensed Rb atoms at finite temperature. Our treatment includes a
self-consistent treatment of the mean-field from finite- excitations and the
anomolous average. This is the first gapless calculation of this type for a
trapped Bose-Einstein condensed gas. The corrections quantitatively account for
the downward shift in the excitation frequencies observed in recent
experiments as the critical temperature is approached.Comment: 4 pages Latex and 2 postscript figure
- ā¦